Network optimization information:
In order to realize the low-pressure hydraulic sealing connection between the mounting flange and the box, one of the following methods can be used.
Add a proper gasket between the flange and the box.
Install the O-ring into the sealing ring groove in the case lip. The minimum seam length shall meet the requirements of O-ring, Crusher hydraulic motor The section diameter is as follows:
When Quantitative hydraulic motor When the check valve diameter is less than or equal to 100mm, the check valve diameter is 2.65mm;
When the diameter of the check valve is more than 100mm and less than or equal to 200mm, the size of the check valve is 3.55mm.
This sealing method is not applicable to situations where the inner diameter A is greater than 200mm.
The chamfer shall be processed at the intersection of the box mounting surface and the mouth hole, and the O-ring shall be placed in the triangle space composed of flange, mouth and chamfer. The size and other details of the O-ring shall be determined by the supplier and the user through consultation.